48T
$299.00
96T
$399.00
Species:
Human
Alternative Name:
B2MG;B2M
Uniport ID:
P61769
Assay Type:
Competitive
unit:
ng/mL
Standard:
2000ng/mL
Sensitivity:
18.75 ng/mL
Detection Range:
31.25-2000ng/mL
Assay Time:
1.5H
Sample Type:
Serum, Plasma, Tissue homogenate and Other biological samples;Sample Volume=50μL
Research:
Tumor immunity;Hepatology;
Test Principle:
This ELISA kit uses the Competitive-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with Human BMG/β2-MG. During the reaction, Human BMG/β2-MG in the sample or standard competes with a fixed amount of Human BMG/β2-MG on the solid phase supporter for sites on the Biotinylated Detection Ab specific to Human BMG/β2-MG. Excess conjugate and unbound sample or standard are washed away, and Avidin-Horseradish Peroxidase (HRP) conjugate are added to each micro plate well and incubated. Then a TMB substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns from blue to yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of Human BMG/β2-MG in tested samples can be calculated by comparing the OD of the samples to the standard curve.
| ng/mL | OD | Corrected |
|---|---|---|
| 2000 | 0.21 | |
| 1000 | 0.346 | |
| 500 | 0.561 | |
| 250 | 0.895 | |
| 125 | 1.323 | |
| 62.5 | 1.715 | |
| 31.25 | 2.091 | |
| 0 | 2.531 |
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.
| Intra-assay Precision | Inter-assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 20 | 20 | 20 | 20 | 20 | 20 |
| Mean(ng/mL) | 29.29 | 495.25 | 575.77 | 40.63 | 405.18 | 735.25 |
| Standard deviation | 5.5 | 21.43 | 35.68 | 3.5 | 23.41 | 46.4 |
| C V (%) | 5.26 | 5.15 | 5.59 | 6.83 | 6.28 | 4.58 |
| Sample Type | Range(%) | Average Recovery(%) |
|---|---|---|
| Serum (n=8) | 82-94 | 88 |
| EDTA plasma (n=8) | 83-99 | 95 |
| Cell culture media (n=8) | 94-105 | 98 |
| Serum (n=5) | EDTA plasma (n=5) | Cell culture media (n=5) | ||
|---|---|---|---|---|
| 1:2 | Range (%) | 81-94 | 80-94 | 83-96 |
| Average (%) | 83 | 92 | 95 | |
| 1:4 | Range (%) | 80-90 | 80-94 | 88-102 |
| Average (%) | 85 | 80 | 101 | |
| 1:8 | Range (%) | 83-95 | 90-99 | 96-107 |
| Average (%) | 88 | 94 | 98 | |
| 1:16 | Range (%) | 86-97 | 87-103 | 89-103 |
| Average (%) | 92 | 100 | 90 |